Bir Göze Refraktif Diğer Göze Difraktif Multifokal Göz İçi Lensi İmplantasyonu Sonrası Görsel Sonuçlar
PDF
Atıf
Paylaş
Talep
Özgün Araştırma
CİLT: 48 SAYI: 1
P: 6 - 14
Şubat 2018

Bir Göze Refraktif Diğer Göze Difraktif Multifokal Göz İçi Lensi İmplantasyonu Sonrası Görsel Sonuçlar

Cyprus J Med Sci 2018;48(1):6-14
1. Manisa Devlet Hastanesi, Göz Hastalıkları Kliniği, Manisa, Türkiye
2. Dokuz Eylül Üniversitesi Tıp Fakültesi, Göz Hastalıkları Anabilim Dalı, İzmir, Türkiye
3. Medipol Üniversitesi Tıp Fakültesi, Göz Hastalıkları Anabilim Dalı, İstanbul, Türkiye
4. Özel Gözakademi Hastanesi, Göz Hastalıkları Kliniği, Denizli, Türkiye
Bilgi mevcut değil.
Bilgi mevcut değil
Alındığı Tarih: 17.03.2017
Kabul Tarihi: 03.07.2017
Yayın Tarihi: 23.02.2018
PDF
Atıf
Paylaş
Talep

ÖZET

Amaç

Katarakt cerrahisinde “mix and match” yaklaşımı ile multifokal göz içi lensi (GİL) implantasyonu yapılan hastaların görsel sonuçlarını değerlendirmektir.

Gereç ve Yöntem

Bu prospektif, randomize olmayan, olgu kontrol çalışmasına 20 hasta (40 göz) dahil edildi. Refraktif multifokal GİL (ReZoom NXG1) hastaların baskın gözlerine implante edilirken, difraktif multifokal GİL (Tecnis ZMA00) baskın olmayan gözlerine implante edildi. Katarakt cerrahisinden 1, 3 ve 6 ay sonra monoküler ve binoküler düzeltilmemiş uzak, ara mesafe ve yakın görme keskinlikleri (logMAR), kontrast duyarlılık düzeyleri ölçüldü. Postoperatif 6. ayda defokus eğrileri, okuma hızları, gözlükten bağımsızlık, halo ve kamaşma semptomları da değerlendirildi. Postoperatif yaşam kalitesi, Ulusal Göz Enstitüsü Görme Fonksiyonu Anketi-25 (National Eye Institute Visual Function Questionnaire-25) anketinin Türkçe versiyonu ile değerlendirildi.

Bulgular

Çalışma grubu, yaş ortalaması 69,45±10,76 (31-86) yıl olan 8 kadın, 12 erkekten oluşmaktaydı. Postoperatif 6. ayda düzeltilmemiş uzak ve ara mesafe görme keskinlikleri ReZoom implante edilen gözlerde Tecnis implante edilenlerden anlamlı olarak daha iyi bulundu (sırasıyla, p=0,026 ve p=0,037). Düzeltilmemiş yakın görme keskinlikleri arasında anlamlı fark bulunmadı (p>0,05). Kontrast duyarlılık, okuma hızı, halo ya da kamaşma açısından gruplar arasında istatistiksel anlamlı fark tespit edilmedi (p<0,05). Hastaların %40’ında düşük derecede halo ya da kamaşma şikayeti tespit edildi. Ortalama hasta memnuniyeti %95 bulundu ve hiç bir hastanın gözlük kullanma ihtiyacı olmadı.

Sonuç

Seçilmiş katarakt hastalarında multifokal GİL’leri birbirini tamamlayacak özelliklerini bir araya getirecek şekilde uygulamak mükemmel görsel sonuç, yüksek hasta memnuniyeti ve gözlükten kurtulma sağlamaktadır.

Anahtar Kelimeler:
Mix and match, multifokal göz içi lensleri, katarakt

Giriş

Presbiyopi halen katarakt cerrahisi ve refraktif cerrahinin en zor optik problemlerinden biridir ve hastaların en önemli isteklerinden biri gözlük kullanmayı bırakmaktır. Katarakt cerrahisi sırasında presbiyopiyi tedavi etmek için çeşitli presbiyopik göz içi lensler (GİL) implante edilmiştir.1,2,3

Hasta seçimi dikkatle yapıldığında multifokal GİL’ler iyi klinik sonuçlar vermektedir.4,5,6,7 Klinik olarak, GİL’lerde difraktif ve refraktif olmak üzere iki çeşit multifokal optik bulunmaktadır. Refraktif multifokal GİL’ler orta ve uzak mesafe için iyi sonuçlar vermektedir, ancak yakın mesafe için elde edilen sonuçlar sınırlıdır.8,9,10,11,12 Difraktif multifokal GİL’ler yakın mesafede çok iyi sonuçlar vermesine karşın orta mesafede efektif olmayabilir.8,9,10,11,12,13,14

ReZoom NXG1 multifokal GİL (Abbott Medical Optics, Santa Ana, CA, ABD) üç parçalı, refraktif, hidrofobik akrilik ultraviyole (UV) engelleyici özelliğe sahip asferik bir GİL’dir ve kenar yansımasını minimize ettiği ve arka kapsül opaklaşmasını önlediği öne sürülen OptiEdge tasarımına sahiptir. Refraktif yüzeyin beş optik bölgesi bulunmaktadır (1., 3. ve 5. bölgeler temel olarak uzak görme ile ilgili iken 2. ve 4. bölgeler yakın görme içindir). Dengeli ara mesafe görüş sağlamak için bölgeler arası geçiş asferik şekilde tasarlanmıştır. Tam görüş sağlaması için %100 ışık geçirgenliğine izin veren yapıdadır.15

Tecnis ZMA00 multifokal GİL (Abbott Medical Optics, Santa Ana, CA, ABD) üç parçalı katlanabilen, difraktif, asferik, UV engelleyici, OptiEdge tasarımına sahip hidrofobik akrilik bir GİL’dir. Modifiye oval ön yüzeyi, sferik sapmaları azaltmak için tasarlanmıştır. Difraktif bölge arka yüzeyde yer almaktadır. Difraktif patern, göze gelen ışığı pupil çapından bağımsız olarak biri uzak biri yakın iki odak düzlemine bölen 32 konsantrik halka ve +4 diyoptri (D) yakın adisyonundan oluşmaktadır.16

Tüm multifokal GİL teknolojilerinde olduğu gibi, bu tasarımlardan her birinin bazı kısıtlılıkları vardır. Katarakt cerrahisinden sonra hasta memnuniyetini arttırmak ve gözlük kullanımına son vermek amacıyla, bir göze refraktif multifokal GİL ve diğer göze difraktif multifokal GİL implantasyonu yapılan “mix and match” yöntemi ilk kez Gunenc tarafından 2000 yılında tanımlanmıştır. Bu yaklaşımın ön sonuçları 2004 yılında ve uzun süreli sonuçları ise 2008 yılında yayımlanmıştır.17,18 Bu tekniğin amacı, odak derinliğini ve görme kalitesini iyileştirmek ile birlikte fotik semptomları ve gözlük kullanımını azaltmak ve uzak, ara mesafe ve yakın görme keskinliğini arttırmaktır.

Bu çalışmada, “mix and match” yaklaşımı ile baskın göze yeni nesil refraktif multifokal GİL (ReZoom NXG1) ve baskın olmayan göze difraktif multifokal GİL (Tennis ZMA00) implant edilmesinin görsel sonuçlar ve hasta memnuniyetine olan etkisini araştırdık.

Gereç ve Yöntem

Bu prospektif çalışmaya kliniğimize başvuran ve bilateral kataraktı olan 20 hastanın (8 kadın, 12 erkek) 40 gözü dahil edildi. “Mix and match” yöntemi kullanılarak tüm hastaların baskın gözlerine ReZoom NXG1 refraktif multifokal GİL ve iki hafta sonra baskın olmayan gözlerine Tennis ZMA00 difraktif multifokal GİL implantasyonu yapıldı. Baskın göz iğne deliği (pinhol) testi ile belirlendi. Tüm hastalar detaylı şekilde bilgilendirildi ve bilgilendirilmiş onamları alındı. Bu çalışma Helsinki Bildirgesi’ne uygun olarak gerçekleştirildi ve çalışma için Dokuz Eylül Üniversitesi yerel etik kurulundan onay alındı.

Bu çalışmaya ameliyattan sonra gözlük veya lens kullanmak istemeyen ve gerçekçi beklentileri olan bilateral katarakt hastaları dahil edildi. Daha önce geçirilmiş göz cerrahisi, katarakt dışında göz hastalığı, 1,00 D’den büyük korneal astigmatizma, aksiyel uzunluğun (AU) 21,0 mm’den küçük veya 26,0 mm’den büyük olması, 5,00 D’den büyük miyopi ve hipermetropi, loş ışıkta pupil genişliğinin 3 mm’den küçük olması ve intraoperatif komplikasyonların varlığı çalışmadan dışlanma kriterleri olarak belirlendi.

GİL gücü hesaplamasında hastanın A-scan ultrason (A-scan Nidek 3000, NIDEK Co., Japonya) ve lazer interferans biyometri (The IOLMaster Versiyon V2,02, Carl Zeiss Meditec AG, Almanya) sonuçlarından her hasta için keratometri, AU ve GİL’nin A sabiti kullanılarak yapıldı. Biyometri aynı doktor tarafından (R.Y.K.) yapıldı. Tüm gözlerde emetropi hedeflendi. Hastanın her iki biyometri ölçümü, AU, keratometrik değerleri, ön kamara derinliği göz önünde bulundurularak implante edilecek multifokal GİL gücü SRK-T formülü ile belirlendi.

Bulgular

Çalışmaya 8 kadın (%40) ve 12 erkekten (%60) oluşan 20 hastanın 40 gözü dahil edildi. Hastaların ortalama yaşı 69,45±10,76 yıl (aralık, 31-86 yıl) idi. Cerrahi öncesi DUGK ortalaması 0,33±0,22 logMAR idi.

Tartışma

Psödofakik presbiyopiyi düzeltmek için monovizyon,21,22 multifokal GİL’ler,6 akomodatif GİL’ler,23 torik multifokal GİL’ler24 ve trifokal GİL’ler25 gibi çeşitli cerrahi teknikler geliştirilmiştir. Refraktif ve difraktif multifokal GİL’lerin “mix and match” konseptiyle kullanımı ilk olarak Günenç ve Çelik17,18 tarafından tanımlanmıştır. Difraktif multifokal GİL’ler iyi düzeyde DUGK ve DYGK sağlarken,26,27 refraktif multifokal GİL’lerin iyi düzeyde DUGK ve DAMGK sağladığı bilinmektedir.27,28,29,30 Farklı GİL’lerin birlikte kullanımı ile cerrahlar hem refraktif hem difraktif lens tasarımlarının avantajlarından yararlanabilirler.

Günenç tarafından yapılan ilk çalışmada,18 10 hastanın bir gözüne difraktif multifokal GİL (811E CeeOn-Difraktif grubu), farklı 10 hastanın bir gözüne refraktif multifokal GİL (Array SA4oN-refraktif grubu) ve başka 10 hastanın bir gözüne refraktif mutlifokal GİL, diğer gözüne ise difraktif multifokal GİL (mix and match grubu) implante edilmiştir. Elde edilen sonuçlara göre, “mix and match” grubundaki hastaların tümünde, refraktif gruptaki hastaların %90’ında ve difraktif gruptaki hastaların %80’inde DUGK 20/25 veya daha iyi bulunmuştur. Bununla birlikte “mix and match” grubundaki hastaların %90’ı gözlükten bağımsız yaşamlarını sürdürebilirken diğer gruplardaki hastalarda bu oran %60 olarak bildilirmiştir. Uzun süreli izlemde tüm hastalar görme işlevlerinden memnun olduklarını bildirmişlerdir.

Günümüzde, ikinci nesil multifokal GİL’lerde, birinci nesil modellerde karşılaşılan bazı sorunlar giderilmiştir. “mix and match” yaklaşımı birçok çalışmada bildirilmiştir. Goes,31 Hütz ve ark.32 ve Lubiński ve ark.33 baskın göze ReZoom ve baskın olmayan göze Tecnis ZM900 implante edilen 20 hastadan elde ettikleri sonuçları bildirmiştir. Benzer şekilde, bu çalışmada 20 hastanın baskın gözlerine ReZoom implante edildi ancak baskın olmayan gözlerde Tecnis ZMA00 tercih edildi (Tablo 5). Bu dört çalışmanın hepsinde, hastaların DUGK, DAMGK ve DYGK’leri memnun edici düzeyde idi ve gözlükten bağımsızlık düzeyleri oldukça yüksekti.

Bu çalışmada, DUGK değeri ReZoom implante edilen gözlerde Tecnis implante edilen gözlere göre anlamlı düzeyde daha düşüktü. İmplantasyondan altı ay sonra, DUGK değeri ReZoom implante edilen gözlerin %95’inde 0,1 logMAR veya daha düşük iken bu oran Tecnis ZMA00 implante edilen gözlerde %70 idi. Tüm hastalarda binoküler DUGK değeri 0,1 logMAR veya daha düşük bulunmuştur (20/20). Hütz ve ark.32 operasyondan sonra 3. ayda, DUGK değerinin ReZoom implante edilen gözlerin %80’inde 0,1 logMAR veya daha düşük iken bu oranın Tecnis ZMA00 implante edilen gözlerde sadece %20 olduğunu bildirdi. Hastaların %85’inde binoküler DUGK değeri 0,1 logMAR veya daha düşük bulundu. Her iki çalışmada da, monoküler DUGK değerleri ReZoom implante edilen gözlerde Tecnis implante edilen gözlerden istatistiksel olarak daha düşük bulundu. Çalışmamızda, DAMGK değeri operasyondan altı ay sonra ReZoom implante edilen gözlerin %65’inde 0,1 logMAR veya daha düşük bulunurken, Tecnis implante edilen gözlerde bu oran %30 idi. ReZoom implante edilen gözlerde monoküler DAMGK değerleri Tecnis implante edilen gözlerden istatistiksel anlamlı düzeyde daha düşük bulundu. Hastaların %95’inde (18/20) binoküler DYGK 0,1 logMAR veya daha düşüktü. Lubiński ve ark.33 hastaların %90’ı operasyondan altı ay sonra 0,0 logMAR DAMGK değerine ulaştığını bildirmiştir. Ancak Lubiński ve ark.33 çalışmasında DAMGK değerlendirilmesi 60 cm mesafede yapılmışken bizim çalışmamızda 100 cm mesafeden değerlendirilmiştir.

Hütz ve ark.32 tarafından yapılan bir çalışmada cerrahiden üç ay sonra DYGK değeri Tecnis implante edilen gözlerin %60’ında 0,1 logMAR veya daha düşük bulunurken ReZoom implante edilen hiçbir gözde bu düzeye ulaşılmamıştır. Hastaların %60’ında binoküler DYGK değeri 0,1 logMAR veya daha düşük bulunmuştur. Çalışmamızda operasyondan sonra 6. ayda DYGK değeri ReZoom implante edilen gözlerin %25’inde Tecnis-ZMA00 implante edilen gözlerin ise %45’inde 0,1 logMAR veya daha düşük bulundu. Hastaların %75’inde binoküler DYGK değeri 0,1 logMAR veya daha düşüktü. Her iki çalışmada da DYGK sonuçları Tecnis implante edilen gözlerde ReZoom implante edilen gözlere göre daha iyiydi. Ancak, sadece Hütz ve ark.’nın32 çalışmasında aradaki farkın istatistiksel olarak anlamlı olduğu bildirilmiştir.

“Mix and match” yaklaşımı kullanılırken, genellikle baskın göze refraktif multifokal GİL implantasyonu önerilir.34 Ancak, Yoon ve ark.,35 eğer hasta sıklıkla yakın mesafe işi yapıyorsa baskın göze difraktif multifokal GİL implanpasyonunu, ve eğer hasta sıklıkla orta mesafe işi yapıyorsa baskın göze refraktif ReZoom implastasyonunu önermektedir. Özel durumlarda baskın göze difraktif multifokal GİL implantasyonu bir seçenek olabilir.

Çalışmamızda, Tecnis implante edilen gözlerde hastanın tercih ettiği en iyi okuma mesafesi istatistiksel olarak anlamlı düzeyde daha yakın bulundu. Okuma hızı hastanın fonksiyonel görme performansı hakkında bilgi verebilir. Çalışmamızda okuma hızı açısından ReZoom ve Tecnis implante edilen gözler arasında istatistiksel olarak anlamlı fark yoktu. Beklendiği gibi ortalama binoküler okuma hızı binoküler karşıtlıkların örtüşmesine bağlı olarak monoküler okuma hızından yüksekti. Chen ve ark.36 ve Hütz ve ark.,32 düşük ve yüksek aydınlatma koşullarında “mix and match” gözlerde memnun edici okuma hızı ve keskinliğine ulaşıldığını bildirmişlerdir.

Buckhurst ve ark.37 bilateral Softech monofokal GİL, bilateral ReZoom, bilateral Tecnis ZM900 veya “mix and match” yöntemi ile sağ göze ReZoom multifokal Gil ve sol göze Tecnis ZM900 implante edilmiş her biri 15 hastadan oluşan dört gruptan elde edilen sonuçları karşılaştırmıştır. ReZoom grubu ile “mix and match” grubu arasında istatistiksel anlamlı fark bulunmazken monofokal ve Tecnis ZM900 grubu ile karşılaştırıldığında ReZoom grubunda en iyi düzeltilmiş orta mesafe GK daha iyi bulunmuştur. Tecnis grubu ile “mix and match” grubu arasında istatistiksel anlamlılıkta bir fark olmamasına rağmen monofokal ve ReZoom grubu ile karşılaştırıldığında Tecnis grubunda en iyi mesafe düzeltilmiş yakın GK daha iyi bulunmuştur. “Mix and match” grubu ReZoom ve Tecnis gruplarıyla benzer sonuçlar vermiştir. Çalışmamızda, -0,5 D’de (uzak görme) ReZoom gözler istatistiksel anlamlı düzeyde üstün bulunurken, Tecnis ZMA00 gözler -3,0 ve -5,0 D aralığında (yakın görme) daha iyi bulundu. ReZoom ve Tecnis implante edilen gözler arasında orta mesafeli görüşte istatistiksel olarak anlamlı fark yoktu. Binoküler görme, yakın mesafede (-2,5 D ile -5,0 D arasında) ReZoom implante edilen gözlerden ve orta mesafede (+1,5 D ile -2,0 D arasında) Tecnis implante edilen gözlerden anlamlı düzeyde daha iyi performans gösterdi. Bu sonuçlar “mix and match” yaklaşımının, bu iki tasarımın avantajlarından yararlanılmasını sağladığını ve görme performansı arttırdığını göstermişlerdir.

Multifokal GİL implantasyonu kontrast duyarlılığının azalmasına neden olabilir ancak bu azalma açısından difraktif ve refraktif multifokal GİL’ler arasında fark yoktur.38 Ancak, Terwee ve ark.39 Tecnis ZM900 ve ZMA00 modellerinin pupil çapından etkilenmemesine karşın ReZoom NXG1 modelinin pupil çapından etkilendiğini ve pupil genişlemesinin ReZoom MGİL implante edilen gözlerde kontrast duyarlılığının azalmasına neden olduğunu göstermiştir. Öte yandan, Yoon ve ark.35 fotopik ve mezopik koşullarda ReZoom NXG1 ve Tecnis ZM900 multifokal GİL’ler arasında istatistiksel anlamlı fark olmadığını, düşük ve yüksek frekanslarda kontrast duyarlılığı seviyelerinin iyi olduğunu bildirmişlerdir. Çalışmamızda, izlem süresince ReZoom NXG1 ve Tecnis ZMA00 gözlerin fotopik ve mezopik kontrast duyarlılık seviyeleri, tüm uzaysal frekanslarda normal sınırlar içinde bulundu. Binoküler kontrast duyarlılık sonuçlarının, monooküler ReZoom ve Tecnis implante edilen gözlerden daha yüksek olduğunu gözlemledik ancak aradaki fark istatistiksel olarak anlamlı değildi. Lubiński ve ark.33 tarafından yapılan çalışmada, binoküler uzak fotopik ve mezopik ile binoküler yakın fotopik kontrast duyarlılığı seviyelerinin yüksek frekanslarda bile normal sınırlar içinde olduğunu bildirmiştir. Bununla beraber, cerrahi sonrası 6. ayda binoküler kontrast duyarlılığının 3. aya göre daha iyi olduğunu belirtmişlerdir.

Kamaşma ve halo gibi fotik fenomenler çok sayıda odak dışı görüntü sonucunda meydana gelir.40 Goes31 tarafından bildirilen hasta seride, 20 hastadan 12’sinde fotik semptomlar mevcutken sadece bir hasta şiddetli fotik fenomen görülmüştür. Lubiński ve ark.33 hiçbir hastada şiddetli halo ya da kamaşma olmadığını, ancak özellikle düşük ışık koşullarında hastaların %75’inde bir miktar kamaşma ve halo meydana geldiğini bildirmişlerdir. Benzer şekilde, Hütz ve ark.32 hastaların %47’sinde hafif halo ve %40’ında şiddetli kamaşma gözlemlediklerini bildirmişlerdir. Yoon ve ark.35 unilateral gruplarda fotik fenomen devam ederken bilateral “mix and match” grubunda semptomların zamanla azaldığını bildirmiştir. Unilateral grupta fakik gözlerde fotik fenomen olmamasının unilateral multifokal GİL takılan gözde oluşan fotik fenomenlere karşı nöroadaptasyonu engelleyebileceğini ileri sürmüşlerdir. Çalışmamızda, cerrahiden sonra 6. ayda iki hasta (%10) orta şiddetli ve sekiz hasta (%40) ise hafif şiddetli halo ve kamaşma yaşadıklarını bildirdiler. Hastalar fotik semptomların günlük yaşamlarında kendilerini rahatsız etmediğini belirttiler. Multifokal GİL’lerin başarısı beynin nöroadaptasyon süresine bağlıdır.41 Nöroadaptasyonun uzun fazının 3-12 ay arasında olduğu varsayılmaktadır. Görme performansının ve hasta memnuniyetinin son değerlendirmesinden önce nöroadaptasyon için yeterli sürenin beklenmesi önemlidir. İzlem süresince hiç bir hastamıza multifokal GİL eksplantasyonu yapılması gerekmedi.

Çalışmamızda, NEI-VFQ-25 anketine göre uzak ve yakın görmede ve sosyal fonksiyonlarda hasta memnuniyeti %90’ın üzerindeydi. Her gün araç kullanan hastaların (n=10) %97’si sürüş sırasındaki görme performansından memnundu. Yamauchi ve ark.42 bilateral Tecnis monofokal GİL ve Tecnis multifokal GİL implantasyonu arasındaki görme performansını karşılaştırmıştır. NEI-VFQ-25 skorları analiz edildiğinde, multifokal grupta monofokal gruba göre sadece gece araba kullanma skorları daha kötü bulunmuştur. Çalışmamızda, hastaların %95’i görme performanslarından memnuniyetlerini “mükemmel veya çok iyi” olarak bildirdi ve yine hastaların %95’i bu yöntemi diğer hastalara önerebileceklerini belirttiler. “mix and match” yaklaşımını kullanan tüm çalışmalarda hasta memnuniyeti ve gözlükten bağımsızlık yüksek düzeyde bulunmuştur.18,31,32,33 “Mix and match” yaklaşımı ile gözlüksüz görme fonksiyonu açısından gerçekçi beklentilere ve yüksek motivasyona sahip hastalarda tatmin edici sonuçlar elde edilebilir.

Sonuç

Sonuç olarak uygun hasta seçimi ile birlikte “mix and match” multifokal GİL implantasyonu psödofakik presbiyopinin düzeltilmesi için iyi bir seçenek olarak düşünülebilir. Bu yaklaşım ile tüm mesafelerde görme keskinliği açısından memnun edici sonuçlar elde edilebilir; yüksek hasta memnuniyeti ve gözlükten kurtulma sağlanabilir. Yüksek hasta memnuniyeti için en önemli faktör uygun hasta seçimi, doğru GİL gücü hesaplaması ve komplikasyonsuz cerrahidir.

Etik

Etik Kurul Onayı: Dokuz Eylül Üniversitesi Tıp Fakültesi Klinik ve Laboratuvar Araştırmaları Etik Kurulu (onay numarası: B.30.2.DEÜ.0.01.00.00/9995).
Hasta Onayı: Alınmıştır.
Hakem Değerlendirmesi: Editörler kurulu dışında olan kişiler tarafından değerlendirilmiştir. 

Yazarlık Katkıları

Cerrahi ve Medikal Uygulama: Üzeyir Günenç, Revan Yıldırım Karabağ, Konsept: Üzeyir Günenç, Hüseyin Aslankara, Dizayn: Üzeyir Günenç, Hüseyin Aslankara, Veri Toplama veya İşleme: Revan Yıldırım Karabağ, Analiz veya Yorumlama: Üzeyir Günenç, Gül Arıkan, Revan Yıldırım Karabağ, Literatür Arama: Revan Yıldırım Karabağ, Rukiye Aydın, Yazan: Revan Yıldırım Karabağ, Rukiye Aydın, Gül Arıkan. Çıkar Çatışması: Yazarlar tarafından çıkar çatışması bildirilmemiştir.
Finansal Destek:Çalışmada kullanılan multifokal GİL’lerin temini için Dokuz Eylül Üniversitesi Rektörlüğü Bilimsel Araştırma Projesi Kordinasyon Birimi’nden finansal destek alınmıştır (BAP proje no: 2009.KB.SAG.089, 2009187).
Surgical Technique
All operations were performed by the same surgeon (U.G.). After the application of topical anesthesia (proparacaine hydrochloride 0.5%), 2.8 mm clear corneal incisions were made in the superior or temporal quadrants, at the steep corneal axis. After filling the anterior chamber with viscoelastic substance, a continuous curvilinear capsulorhexis was created with a diameter of approximately 5 mm. After creating two side ports, hydrodissection was performed. The nucleus and epinucleus were aspirated by phacoemulsification, and cortical cleaning was accomplished by bimanual irrigation/aspiration. The capsular bag and anterior chamber were filled with viscoelastic substance. Both IOLs were inserted using the UNFOLDER® Emerald XL delivery system (Abbott Medical Optics, Santa Ana, CA, USA). The viscoelastic substance was aspirated by bimanual irrigation/aspiration, and the operation was completed with stromal hydration and intracameral 1% cefuroxime injection. There were no intraoperative or postoperative complications. After surgery, patients received prednisolone acetate 1% and ofloxacin 0.3% eye drops 6 times per day for the first postoperative week. Ofloxacin was stopped at the end of the first week and patients were advised to continue prednisolone acetate 4 times per day for 3 weeks.
Cerrahi Teknik
Tüm cerrahi girişimler aynı doktor (Ü.G.) tarafından gerçekleştirildi. Topikal anestezi (proparakain hidroklorür %0,5) yapıldıktan sonra, 2,8 mm’lik saydam korneal kesi dik olan korneal aksın bulunduğu üst veya temporal kadrandan yapıldı. Ön kamara viskoelastik madde ile doldurulduktan sonra, yaklaşık 5 mm çapında sürekli dairesel kapsüloreksis yapıldı. İki yan giriş açıldıktan sonra hidrodisseksiyon yapıldı. Fakoemülsifikasyon ile nükleus ve epinükleus aspire edildi ve bimanuel irrigasyon/aspirasyon ile kortikal temizlik yapıldı. Kapsüler kese ve ön kamara viskoelastik madde ile dolduruldu. Her iki GİL de UNFOLDER® Emerald XL sistemi (Abbott Medical Optics, Santa Ana, CA, ABD) kullanılarak yerleştirildi. Viskoelastik madde bimanuel irrigasyon/aspirasyon ile uzaklaştırıldı ve operasyon stromal hidrasyon ve ön kamaraya %1’lik sefuroksim enjeksiyonu ile tamamlandı. Cerrahi işlem sırasında veya sonrasında herhangi bir komplikasyon ile karşılaşılmadı. Cerrahiden sonra, hastalar postoperatif ilk hafta boyunca günde 6 kez %1’lik prednizolon astetat ve %0,3’lük ofloksasin göz damlası kullandı. İlk hafta sonunda ofloksasin kesildi ve hastalara sonraki üç hafta boyunca günde dört kez prednizolon asetat kullanmaları önerildi.
Spherical Equivalent Values
At postoperative 6 months, the mean spherical equivalent was -0.04±0.12 D in ReZoom-implanted eyes and -0.11±0.2 D in Tecnis-implanted eyes. There was no statistically significant difference in spherical equivalent values between refractive and diffractive groups at 1, 3, or 6 months postoperatively (p>0.05).
Sferik Eşdeğerler
Cerrahi sonrası 6. ayda, ortalama sferik eşdeğer ReZoom implante edilen gözlerde -0,04±0,12 D ve Tecnis implante edilen gözlerde -0,11±0,2 D idi. Cerrahi sonrası 1., 3. ve 6. aylardaki refraktif ve difraktif gruplar arasında sferik eşdeğer açısından istatistiksel fark yoktu (p>0,05).
Study Limitation
A limitation of the present study is the lack of a control group of patients implanted with bilateral refractive and bilateral diffractive multifocal IOLs. Prospective, randomized, double-blind studies assessing bilateral refractive, bilateral diffractive, bilateral trifocal, and “mix and match” multifocal IOL implantation are needed.
Çalışmanın Kısıtlılıkları
Bilateral refraktif ve bilateral difraktif multifokal GİL implante edilen kontrol grubunun olmaması bu çalışmanın kısıtlılıklarından biridir. Bilateral refraktif, bilateral difraktif, bilateral trifokal ve “mix and match” multifokal GİL implantasyonlarını değerlendiren prospektif, randomize ve çift-kör çalışmalara ihtiyaç vardır.
Outcome Measurements
Patients were examined for anterior segment findings at 1 and 7 days following surgery. Patients were evaluated at 1, 3, and 6 months postoperatively. At every follow-up visit, spherical equivalent values, keratometry, monocular and binocular uncorrected distance visual acuity (UDVA) at 4 meters using Early Treatment of Diabetic Retinopathy Study (ETDRS) chart, monocular and binocular uncorrected near visual acuity (UNVA) using ETDRS Near LogMAR Chart 2000 (Precision Vision, LaSalle, IL) at 40 cm, and monocular and binocular uncorrected intermediate visual acuity (UIVA) with ETDRS Near LogMAR Chart 2000 at 100 cm were assessed. Results were evaluated using logMAR visual acuities.19 Monocular and binocular contrast sensitivity under photopic (85 cd/m2) and mesopic (3 cd/m2) conditions was measured using the Functional Acuity Contrast Test Chart of the Optec 6500 vision tester (Stereo Optical, Chicago, Illinois, USA).
At 6 months after surgery, defocus curve and focus depth (NIDEK RT-5100 Foropter, NIDEK CO., LTD.), and monocular and binocular reading speed under the same conditions using Turkish version of MNREAD (Minnesota Low Vision Reading Test) cards20 were measured. Every sentence of MNREAD card consists of 3 lines and 60 characters. Chart 1 and 2 include 19 logarithmic sentences in the logMAR range of -0.5 to 1.3 with 0.1 logarithmic intervals. Patients were asked to read a sentence as fast and accurately as possible while the sentences below were covered with a piece of paper. Patients reading speed was evaluated from the beginning until the critical print size, which was the smallest print size the patient could read at maximum reading speed. Reading time was measured with a stopwatch. Reading time and number of errors were recorded for each sentence. Patients’ right eyes were evaluated with chart 1 and left eyes with chart 2. Then binocular reading speed was measured with chart 1. Reading speed was calculated using the following formula: reading speed (words/min)=60 ´ (10 - number of errors)/time (s).
Quality of life, halo, glare phenomena, spectacle independence, adaption time to photic phenomena, and eye preference were also evaluated at 6 months after surgery. The Turkish version of the National Eye Institute Visual Functioning Questionnaire-25 (NEI VFQ-25) was used to evaluate the patients’ quality of life.21 Patients who had halo and glare were asked to grade phenomena on a scale of mild, moderate, or severe. The patients were also asked whether they would suggest the “mix and match” approach to other patients. For all measurements, monocular examinations (first right eyes, then left eyes) were done before binocular examinations.
Ölçüm Sonuçları
Hastalar cerrahiyi takiben 1. ve 7. günlerde muayene edilerek ön kamara bulguları değerlendirildi. Hastalar postoperatif 1., 3. ve 6. ayda muayene edildi. Her izlemde, sferik eşdeğer, keratometri, Erken Diyabetik Retinopati Tedavisi Çalışması (ETDRS) eşeli kullanılarak 4 metrede monoküler ve binoküler düzeltilmemiş uzak görme keskinliği (DUGK), 40 cm’de ETDRS yakın LogMAR eşeli 2000 (Precision Vision, LaSalle, IL) kullanılarak monoküler ve binoküler düzeltilmemiş yakın görme keskinliği (DYGK) ve 100 cm’de ETDRS yakın LogMAR eşeli 2000 kullanılarak monoküler ve binoküler düzeltilmemiş ara mesafe değerlendirildi. Sonuçlar LogMAR görme keskinliği değerleri kullanılarak analiz edildi.19 Monoküler ve binoküler kontrast sensitivitesi, Optec 6500 görme test cihazının fonksiyonel keskinlik kontrast test eşeli (Stereo Optical, Chicago, Illinois, ABD) kullanılarak fotopik (85 cd/m2) ve mezopik (3 cd/m2) koşullarda ölçüldü.
Cerrahiden sonra 6. ayda, odak derinliği ve defokus eğrisi NIDEK RT-5100 Foropter (NIDEK Co., LTD.) ve MNREAD (Minnesota Low Vision Reading Test) kartlarının Türkçe versiyonu ile aynı koşullarda yapılan monoküler ve binoküler okuma hızları ölçüldü.20 MNREAD kartındaki her cümle üç satır ve 60 karakterden oluşmaktadır. Çizelge 1 ve 2, logMAR ölçeğinde 0,1 logaritmik aralıklı -0,5 ile 1,3 arasında değişen 19 logaritmik cümle içermektedir. Altta bulunan cümleler bir kağıt parçası ile kapatılırken, hastalardan görünen cümleyi mümkün olduğunca hızlı ve doğru bir şekilde okumaları istendi. Hastaların başlangıçtan itibaren, maksimum hızda okuyabildikleri en küçük yazı boyutu olan kritik yazı boyutuna kadarki okuma hızları değerlendirildi. Okuma zamanı kronometre ile ölçüldü. Her cümle için okuma zamanı ve yapılan hata sayısı kaydedildi. Hastaların sağ gözleri çizelge 1 ile, sol gözleri ise çizelge 2 ile değerlendirildi. Daha sonra, binoküler okuma hızı çizelge 1 ile ölçüldü. Okuma hızı hesaplanırken okuma hızı (kelime/dk)=60 x (10 - hata sayısı)/süre (saniye) formülü kullanıldı.
Yaşam kalitesi, halo, kamaşma, gözlükten bağımsızlık, fotik fenomenlere adaptasyon süresi ve göz tercihi de cerrahiden altı ay sonra değerlendirildi. Hastaların yaşam kaliteleri, Ulusal Göz Enstitüsü Görme Fonksiyonu Anketi-25’in (NEI-VFQ-25) Türkçe sürümü kullanılarak değerlendirildi. Halo ve kamaşması olan hastalardan bu olayları hafif, orta ve şiddetli olmak üzere derecelendirmeleri istendi. Ayrıca bu hastalara “mix and match” yaklaşımını diğer hastalara önerip önermeyecekleri soruldu. Tüm ölçümlerde monoküler muayene (önce sağ göz, daha sonra sol göz olacak şekilde) binoküler muayeneden önce gerçekleştirildi.
Visual Acuity Outcomes
Visual acuity outcomes were not significantly different at 1, 3, or 6 months postoperatively, therefore only the 6-month results are presented.
Görme Keskinliği Sonuçları
Cerrahi sonrası 1., 3. ve 6. aylarda görme keskinliği sonuçları arasında istatistiksel anlamlı fark yoktu, bu sebeple sadece 6. ay sonuçları sunulmaktadır.
Statistical Analysis
Data were evaluated using SPSS version 15.0 software. For complementary analysis, mean values, standard deviation, and percentage values were used. Visual acuity values were converted to logMAR equivalents for statistical analysis.19 Visual functions of the refractive and diffractive groups were compared using the Mann-Whitney U test. Friedman test was applied to compare visual acuities and spherical equivalent values at 1, 3, and 6 months postoperatively. Spearman correlation analysis was used to determine whether there is a correlation between the patient satisfaction and postoperative results at 6 months. A p value less than 0.05 was considered statistically significant.
İstatistiksel Analiz
Veriler SPSS 15.0 versiyonu yazılım paketi kullanılarak değerlendirildi. Tamamlayıcı analizler için ortalama değerler, standart sapma ve yüzde değerler kullanıldı. Görme keskinliği değerleri istatistiksel analiz için logMAR eşdeğerlerine dönüştürüldü.19 Refraktif ve difraktif grupların görme fonksiyonları Mann-Whitney U testi kullanılarak karşılaştırıldı. Görme keskinlikleri ile ameliyat sonrası 1., 3. ve 6. aylardaki sferik eşdeğerlerin karşılaştırılmasında Friedman testi kullanıldı. Hasta memnuniyeti ile ameliyat sonrası 6. aydaki sonuçlar arasında korelasyon olup olmadığı Spearman korelasyon analizi ile değerlendirildi. İstatistiksel olarak p değerinin 0,05’ten küçük olması anlamlı kabul edildi.
Monocular Distance Visual Acuity
All eyes achieved UDVA of 0.2 logMAR or better in the refractive group, compared with 90% of the eyes in the diffractive group. Mean UDVA was 0.00±0.09 logMAR in the refractive group and 0.09±0.13 logMAR in the diffractive group. UDVA was significantly better in the refractive group than the diffractive group (p=0.026) (Table 1).
Monoküler Uzak Görme Keskinliği
Difraktif gruptaki gözlerin %90’ı ve refraktif gruptaki tüm gözler 0,2 logMAR veya daha iyi DUGK’ye ulaştı. Ortalama DUGK refraktif grupta 0,00±0,09 logMAR ve difraktif grupta 0,09±0,13 logMAR idi. DUGK’nin refraktif grupta, difraktif gruba kıyasla, istatistiksel olarak anlamlı düzeyde daha iyi olduğu görüldü (p=0,026) Tablo 1).
Monocular Near Visual Acuity
Sixty-five percent of the eyes in the refractive group achieved a UNVA of 0.2 logMAR or better, compared with 80% of the eyes in the diffractive group. Mean UNVA was 0.24±0.14 logMAR in the refractive group and 0.16±0.1 logMAR in the diffractive group. No statistically significant difference was noted between the groups (p>0.05) (Table 2).
At postoperative 6 months, the patients were asked to hold the near chart where they could best read it. Mean patient-preferred reading distance was 32.1±3.0 cm in the diffractive eyes and 35.85±6.05 cm in the refractive eyes. The patients’ best binocular reading distance was 33.75±3.55 cm. Patient-preferred reading distance was statistically significant closer in diffractive eyes (p=0.034).
Monoküler Yakın Görme Keskinliği
Difraktif gruptaki gözlerin %80’i ve refraktif gruptaki gözlerin %65’i 0,2 logMAR veya daha iyi DYGK’ye ulaştı. Ortalama DYGK, refraktif grupta 0,24±0,14 logMAR ve difraktif grupta 0,16±0,1 logMAR olarak bulundu. Gruplar arasında istatistiksel anlamlı bir fark yoktu (p>0,05) (Tablo 2).
Cerrahiden sonra 6. ayda, hastalardan yakın eşelini en iyi okuyabildikleri yerde tutmaları istendi. Hastaların tercih ettikleri ortalama okuma mesafesi difraktif gözlerde 32,1±3,0 cm ve refraktif gözlerde 35,85±6,05 cm olarak bulundu. Hastaların en iyi binoküler okuma uzaklığı 33,75±3,55 cm idi. Difraktif gözlerde hastaların tercih ettikleri okuma uzaklığı istatistiksel anlamlı düzeyde daha yakın mesafedeydi (p=0,034).
Monocular Intermediate Visual Acuity
All eyes achieved UIVA of 0.2 logMAR or better in the refractive group, compared with 80% of the eyes in the diffractive group. Mean UIVA was 0.14±0.22 logMAR in the refractive group and 0.19±0.13 logMAR in the diffractive group. The refractive group had significant better intermediate vision (p=0.037) (Table 3).
Figure 1 shows monocular and binocular UDVA, UIVA, and UNVA values at 1 month, 3 months, and 6 months postoperatively.
Monoküler Ara Mesafe Görme Keskinliği
Difraktif gruptaki gözlerin %80’i ve refraktif gruptaki tüm gözler 0,2 logMAR veya daha iyi düzeltilmemiş ara mesafe görme keskinliği (DAMGK) değerine ulaştı. Ortalama DAMGK, refraktif grupta 0,14±0,22 logMAR ve difraktif grupta 0,19±0,13 logMAR olarak ölçüldü. Refraktif grupta ara mesafe görme istatistiksel olarak daha iyi bulundu (p=0,037) (Tablo 3).
Şekil 1’de cerrahiden sonra 1., 3. ve 6. ay monoküler ve binoküler DUGK, DYGK ve DAMGK değerleri gösterilmektedir.
Binocular Visual Acuity
The patients’ mean binocular UDVA, UIVA, and UNVA levels at postoperative 1, 3, and 6 months are shown in Table 4. At the 6-month postoperative visit, all patients achieved an UDVA of 0.1 logMAR or better. Fifteen patients (75%) achieved an UNVA of 0.1 logMAR or better and 18 patients (90%) achieved an UIVA of 0.1 logMAR or better.
Figure 1 shows the monocular and binocular UDVA, UIVA, and UNVA at 1, 3, and 6 months postoperatively. Binocular visual acuity results were better than monocular results at all distances throughout the follow-up.
Binoküler Görme Keskinliği
Cerrahiden sonra 1., 3. ve 6. aylardaki binoküler DUGK, DYGK ve DAMGK düzeyleri Tablo 4’te gösterilmektedir. Cerrahiden sonra 6. aydaki izlemde, tüm hastalar 0,1 logMAR veya daha iyi DUGK’ye ulaştı. On beş hasta (%75) 0,1 logMAR veya daha iyi DYGK değerine ve 18 hasta (%90) 0,1 logMAR veya daha iyi DAMGK değerine ulaştı.
Şekil 1 cerrahiden sonra 1., 3. ve 6. aylardaki DUGK, DYGK ve DAMGK değerlerini göstermektedir. İzlemler boyunca tüm uzaklıklarda binoküler görme keskinliği sonuçları monoküler sonuçlardan daha iyi bulundu.
Contrast Sensitivity
Contrast sensitivity levels of the all binocular, refractive, and diffractive groups were within normal limits both under photopic and mesopic conditions throughout follow-up. No statistically significant difference was noted between the refractive and diffractive groups at any spatial frequencies under photopic or mesopic conditions at 1, 3, or 6 months postoperatively (p>0.05). Figures 2 and 3 shows the contrast sensitivity curves of the binocular, refractive, and diffractive eyes in photopic and mesopic conditions at 6 months postoperatively.
Kontrast Duyarlılığı
İzlem süresi içince tüm binoküler, refraktif ve difraktif grupların kontrast duyarlılık seviyesi fotopik ve mezopik koşullarda normal sınırlarda bulundu. Cerrahi sonrası 1.,3. ve 6. aylarda fotopik ve mezopik koşullar altında tüm uzaysal frekanslarda refraktif ve difraktif gruplar arasında kontrast duyarlılığı açısından istatistiksel anlamlı fark yoktu (p>0,05). Şekil 2 ve 3’te cerrahi sonrası 6. aydaki binoküler, refraktif ve difraktif gözlerin fotopik ve mezopik koşullarda kontrast duyarlılığı eğrisi gösterilmektedir.
Defocus Curve
The diffractive eyes were significantly better than the refractive eyes between +4.00 and +3.00 D (p<0.05) and between -3.00 D and -5.00 D (p<0.05). The refractive eyes were significantly better than the diffractive eyes at +0.5 D (p=0.038). There was no statistically significant difference between diffractive and refractive eyes with regards to intermediate distance.
Binocular vision achieved the best results at all distances in the defocus curve. The binocular vision results were significantly better than those of diffractive eyes between +1.50 and -2.00 D (p<0.05) and those of refractive eyes between +4.00 and +1.50 D (p<0.05) and between -2.50 and -5.00 D (p<0.05).
Mean depth of focus of the refractive, diffractive, and binocular group were 5.0 D, 5.5 D, and 6.0 D, respectively. Figure 4 shows the defocus curves of all groups at 6 months postoperatively.
Defokus Eğrisi
Difraktif gözler +4,00 D ve +3,00 D arasında (p<0,05) ve -3,00 D ve -5,00 D arasında (p<0,05) refraktif gözlerden istatistiksel anlamlı düzeyde daha iyi bulundu. Refraktif gözler +0,5 D’de difraktif gözlerden daha iyi idi (p=0,038). Ara mesafede difraktif ve refraktif gözler arasında istatistiksel anlamlı fark yoktu. Binoküler görme defokus eğrisindeki tüm uzaklıklarda en iyi sonuca ulaştı. Binoküler görme sonuçları, difraktif gözlere göre +1,50 D ve -2,00 D arasında (p<0,05) ve refraktif gözlere göre +4,00 D ve +1,50 D arasında (p<0,05) ve -2,50 D ve -5,00 D (p<0,05) arasında istatistiksel anlamlı düzeyde daha iyi bulundu. Refraktif, difraktif ve binoküler grupların ortalama odak derinlikleri sırasıyla 5,0 D, 5,5 D ve 6,0 D olarak ölçüldü. Şekil 4’te tüm grupların cerrahiden sonra 6. aydaki defokus eğrileri gösterilmektedir.
Spectacle Independence
All patients had satisfactory spectacle-free visual function in their daily life during the follow-up period.
Gözlükten Bağımsızlık
İzlem boyunca tüm hastaların gündelik yaşamlarında gözlüksüz görme düzeylerinden memnun olduğu görüldü.
Subjective Symptoms and Patient Satisfaction
According to NEI VFQ-25 questionnaire results, patient satisfaction was 90% or above with regards to distance and near activities, social functions, and driving. Ninety-five percent of the patients stated that they would suggest multifocal IOL implantation with the “mix and match” approach to other patients. When asked whether there was any difference between each eye’s visual acuity and visual quality, 5 patients (25%) preferred the vision in their refractive eye and 2 patients (10%) preferred the vision in their diffractive eye, while 13 patients (65%) reported no difference between the two eyes.
In terms of photic phenomena such as halo and glare, 11 patients (55%) reported mild and 5 patients (25%) reported moderate symptoms at postoperative 3 months. Eight patients (40%) reported mild and 2 patients (10%) reported moderate symptoms at postoperative 6 months. One patient reported symptoms in the diffractive eye only, while the other patients reported equal symptoms in both eyes. Only one patient in the early postoperative period reported watching TV with sunglasses due to severe glare. The severity of the symptom decreased at the end of the second postoperative month. At postoperative 6 months, one patient had complaints of mild glare. However, it did not cause any difficulty in the patient’s daily life. When the patients were asked how long it took to get used to photic phenomena, the average time needed to adapt was 28.4±37.1 days (0-120 days). Ninety-five percent of the patients reported their distance, intermediate, and near visual acuity as “perfect or very good”.
Subjektif Semptomlar ve Hasta Memnuniyeti
NEI-VFQ-25 anketi sonuçlarına göre, uzak ve yakın aktivite, sosyal işlevler ve araba kullanma konularında hasta memnuniyeti %90 ve üzerinde idi. Hastaların %95’i “mix and match” yaklaşımı ile multifokal GİL implantasyonunu diğer hastalara önerebileceklerini belirtti. Görme keskinliği ve kalite açısından iki göz arasındaki fark sorgulandığında, 13 hasta (%65) iki göz arasında fark olmadığını belirtirken, beş hasta (%25) refraktif gözdeki görmeyi, iki hasta (%10) ise difraktif gözdeki görmeyi tercih ettiklerini belirtti.
Cerrahiden sonra 3. ayda halo ve kamaşma gibi fotik olaylar açısından 11 hasta (%55) hafif ve 5 hasta (%25) orta şiddette semptomları olduğunu bildirdi. Cerrahiden 6 ay sonra 8 hasta (%40) hafif ve 2 hasta (%10) ise orta şiddette semptomları olduğunu bildirdi. Bir hastada semptomlar sadece difraktif gözde iken, diğer hastalarda iki gözde de semptomlar eşit düzeydeydi. Sadece bir hasta cerrahiden sonra erken dönemde aşırı kamaşma sebebiyle güneş gözlüğü ile televizyon izlediğini bildirdi. Bu hastada semptomun şiddeti cerrahiden sonra 2. ayın sonunda azaldı. Operasyondan altı ay sonra bir hastada hafif kamaşma şikayetleri vardı. Ancak, bu durum hastanın gündelik yaşamını zorlaştırmayacak düzeydeydi. Hastalara fotik fenomene alışmanın ne kadar sürdüğü sorulduğunda ortalama alışma süresinin 28,4±37,1 gün (0-120 gün) olduğu görüldü. Hastaların %95’i uzak, ara ve yakın mesafede görme keskinliklerinin “mükemmel veya çok iyi” olduğunu belirtti.
Reading Speed
Patients’ mean reading speed in both refractive and diffractive eyes was the same, at 166 words/min. Binocular mean reading speed was 177 words/min. None of the patients had posterior capsular opacification or IOL dislocation during the follow-up period.
Okuma Hızı
Hastaların hem refraktif hem de difraktif gözde ortalama okuma hızları eşitti ve 166 kelime/dk olarak bulundu. Binoküler ortalama okuma hızı 177 kelime/dk idi. İzlem süresi boyunca hiçbir hastada arka kapsül kesafeti veya GİL dislokasyonu meydana gelmedi.

Kaynaklar

1
Gooi P, Ahmed IK. Review of presbyopic IOLs: multifocal and accommodating IOLs. Int Ophthalmol Clin. 2012;52:41–50. [PubMed] [Google Scholar]
2
Agresta B, Knorz MC, Kohnen T, Donatti C, Jackson D. Distance and Near Visual Acuity Improvement After Implantation of Multifocal Intraocular Lenses in Cataract Patients With Presbyopia: A Systematic Review. J Refract Surg. 2012;28:426–435. [PubMed] [Google Scholar]
3
Lichtinger A, Rootman DS. Intraocular lenses for presbyopia correction. Curr Opin Ophthalmol. 2012;23:40–46. [PubMed] [Google Scholar]
4
Lacmanović-Loncar V, Pavicić-Astalos J, Petric-Vicković I, Mandić Z. Multifocal intraocular “mix and match” lenses. Acta Clin Croat. 2008;47:217–220. [PubMed] [Google Scholar]
5
Bellucci R. Multifocal intraocular lenses. Curr Opin Ophthalmol. 2005;16:33–37. [PubMed] [Google Scholar]
6
De Vries NE, Nuijts RM. Multifocal intraocular lenses in cataract surgery: Literature review of benefits and side effects. J Cataract Refract Surg. 2013;39:268–278. [PubMed] [Google Scholar]
7
Lane SS, orris M, Nordan L, Packer M, Tarantino N, Wallace RB 3 rd. Multifocal intraocular lenses. Ophthalmol Clin North Am. 2006;19:89–105. [PubMed] [Google Scholar]
8
Chiam PJ, Chan JH, Haider SI, Karia N, Kasaby H, Aggarwal RK. Functional vision with bilateral ReZoom and ReSTOR intraocular lenses 6 months after cataract surgery. J Cataract Refract Surg. 2007;33:2057–2061. [PubMed] [Google Scholar]
9
Alió JL, rabner G, Plaza-Puche AB, Rasp M, Piñero DP, Seyeddain O, Rodríguez-Prats JL, Ayala MJ, Moreu R, Hohensinn M, Riha W, Dexl A. Postoperative bilateral reading performance with 4 intraocular lens models: Six-month results. J Cataract Refract Surg. 2011;37:842–852. [PubMed] [Google Scholar]
10
Van Der Linden JW, Van Velthoven M, Van Der Meulen I, Nieuwendaal C, ourits M, Lapid-Gortzak R. Comparison of a new-generation sectorial addition multifocal intraocular lens and a diffractive apodized multifocal intraocular lens. J Cataract Refract Surg. 2012;38:68–73. [PubMed] [Google Scholar]
11
Alió JL, Plaza-Puche AB, avaloy J, Ayala MJ. Comparison of the Visual and Intraocular Optical Performance of a Refractive Multifocal IOL With Rotational Asymmetry and an Apodized Diffractive Multifocal IOL. J Refract Surg. 2012;28:100–105. [PubMed] [Google Scholar]
12
Cillino S, Casuccio A, Di Pace F, Morreale R, Pillitteri F, Cillino G, Lodato G. One-Year Outcomes with New-Generation Multifocal Intraocular Lenses. Ophthalmology. 2008;115:1508–1516. [PubMed] [Google Scholar]
13
Blaylock JF, Si Z, Vickers C. Visual and refractive status at different focal distances after implantation of the ReSTOR multifocal intraocular lens. J Cataract Refract Surg. 2006;32:1464–1473. [PubMed] [Google Scholar]
14
Kohnen T, Allen D, Boureau C, Dublineau P, Hartmann C, Mehdorn E, Rozot P, Tassinari G. European Multicenter Study of the AcrySof ReSTOR Apodized Diffractive Intraocular Lens. Ophthalmology. 2006;113:584. [PubMed] [Google Scholar]
15
Product Insert. Abbott Medical Optics. Santa Ana, CA, USA. 2010 [Google Scholar]
16
Product Insert. Abbott Medical Optics. Santa Ana, CA, USA. 2011 [Google Scholar]
17
Gunenc U, Celik L. Multifocal intraocular lenses: clinical eval- uation of diffractive versus refractive designs. Med Netw Ophthalmol. 2004;11:4–11. [Google Scholar]
18
Gunenc U, Celik L. Long-term experience with mixing and matching refractive array and diffractive CeeOn multifocal intraocular lenses. J Refract Surg. 2008;24:233–242. [PubMed] [Google Scholar]
19
Holladay JT. Proper method for calculating average visual acuity. J Refract Surg. 1997;13:388–391. [PubMed] [Google Scholar]
20
İdil Ş, Çalişkan D, İdil N. Development and validation of the Turkish version of the MNREAD visual acuity charts. Turk J Med Sci. 2011;41:565–570. [Google Scholar]
21
Jain S, Arora I, Azar DT. Success of monovision in presbyopes: review of the literature and potential applications to refractive surgery. Surv Ophthalmol. 1996;40:491–499. [PubMed] [Google Scholar]
22
Greenbaum S. Monovision pseudophakia. J Cataract Refract Surg. 2002;28:1439–1443. [PubMed] [Google Scholar]
23
Cumming JS, Colvard DM, Dell SJ, Doane J, Fine IH, Hoffman RS, Packer M, Slade SG. Clinical evaluation of the Crystalens AT-45 accommodating intraocular lens: results of the U.S. Food and Drug Administration clinical trial. J Cataract Refract Surg. 2006;32:812–825. [PubMed] [Google Scholar]
24
Visser N, Nuijts RM, de Vries NE, Bauer NJ. Visual outcomes and patient satisfaction after cataract surgery with toric multifocal intraocular lens implantation. J Cataract Refract Surg. 2011;37:2034–2042. [PubMed] [Google Scholar]
25
Shen Z, Lin Y, Zhu Y, Liu X, Yan J, Yao K. Clinical comparison of patient outcomes following implantation of trifocal or bifocal intraocular lenses: a systematic review and meta-analysis. Sci Rep. 2017;7:45337. [PMC free article] [PubMed] [Google Scholar]
26
Forte R, Ursoleo P. The ReZoom multifocal intraocular lens: 2-year follow-up. Eur J Ophthalmol. 2009;19:380–383. [PubMed] [Google Scholar]
27
C Mesci, Y Karakurt, N Aydın, Z Aslan, H Acar HE. Difraktif (Restor) ve Refraktif (Rezoom) Multifokal Göz İçi Lenslerle Katarakt Ameliyatları Sonrası Görme Fonksiyonlarının Karşılaştırması Glo-Kat. 2009;4:183–188. [Google Scholar]
28
Pepose JS, Qazi MA, Davies J, Doane JF, Loden JC, Sivalingham V, Mahmoud AM. Visual Performance of Patients with Bilateral vs Combination Crystalens, ReZoom, and ReSTOR Intraocular Lens Implants. Am J Ophthalmol. 2007;144:347–357. [PubMed] [Google Scholar]
29
Akaishi L, Vaz R, Vilella G, Garcez RC, Tzelikis PF. Visual Performance of Tecnis ZM900 Diffractive Multifocal IOL after 2500 Implants: A 3-Year Followup. J Ophthalmol. 2010;2010 [PMC free article] [PubMed] [Google Scholar]
30
Pieh S, Marvan P, Lackner B, Hanselmayer G, Schmidinger G, Leitgeb R, Sticker M, Hitzenberger CK, Fercher AF, Skorpik C. Quantitative performance of bifocal and multifocal intraocular lenses in a model eye: point spread function in multifocal intraocular lenses. Arch Ophthalmol. 2002;120:23–28. [PubMed] [Google Scholar]
31
Goes FJ. Visual results following implantation of a refractive multifocal IOL in one eye and a diffractive multifocal IOL in the contralateral eye. J Refract Surg. 2008;24:300–305. [PubMed] [Google Scholar]
32
Hütz WW, Bahner K, Röhrig B, Hengerer F. The combination of diffractive and refractive multifocal intraocular lenses to provide full visual function after cataract surgery. Eur J Ophthalmol. 2010;20:370–375. [PubMed] [Google Scholar]
33
Lubiński W, Podboraczyńska-Jodko K, Gronkowska-Serafin J, Karczewicz D. Visual outcomes three and six months after implantation of diffractive and refractive multifocal IOL combinations. Klin Oczna. 2011;113:209–215. [PubMed] [Google Scholar]
34
Knorz MC. Multifocal intraocular lenses: overview of their capabilities, limitations, and clinical benefits. J Refract Surg. 2008;24:215–217. [PubMed] [Google Scholar]
35
Yoon SY, Song IS, Kim JY, Kim MJ, Tchah H. Bilateral mix-and-match versus unilateral multifocal intraocular lens implantation: Long-term comparison. J Cataract Refract Surg. 2013;39:1682–1690. [PubMed] [Google Scholar]
36
Chen W, Meng Q, Ye H, Liu Y. Reading ability and stereoacuity with combined implantation of refractive and diffractive multifocal intraocular lenses. Acta Ophthalmol. 2011;89:376–381. [PubMed] [Google Scholar]
37
Buckhurst PJ, Wolffsohn JS, Naroo SA, Davies LN, Bhogal GK, Kipioti A, hah S. Multifocal Intraocular Lens Differentiation Using Defocus Curves. Investig Opthalmology Vis Sci. 2012;53:3920–3926. [PubMed] [Google Scholar]
38
Ravalico G, Baccara F, Rinaldi G. Contrast sensitivity in multifocal intraocular lenses. J Cataract Refract Surg. 1993;19:22–25. [PubMed] [Google Scholar]
39
Terwee T, Weeber H, van der ooren M, iers P. Visualization of the retinal image in an eye model with spherical and aspheric, diffractive, and refractive multifocal intraocular lenses. J Refract Surg. 2008;24:223–232. [PubMed] [Google Scholar]
40
Dick HB, Krummenauer F, Schwenn O, Krist R, Pfeiffer N. Objective and subjective evaluation of photic phenomena after monofocal and multifocal intraocular lens implantation. Ophthalmology. 1999;106:1878–1886. [PubMed] [Google Scholar]
41
Aslan BS, Akyol N. Katarakt Cerrahisinde Multifokal Göziçi Lensleri ve Nöroadaptasyon. Glo-Kat. 2008;3:1–4. [Google Scholar]
42
Yamauchi T, Tabuchi H, Takase K, Ohsugi H, Ohara Z, Kiuchi Y. Comparison of visual performance of multifocal intraocular lenses with same material monofocal intraocular lenses. PLoS One. 2013;8:e68236. [PMC free article] [PubMed] [Google Scholar]